Explanation of the Setting Parameters | |||
Notice: To change the display settings,please read the detail description of 6.1 to 6.9,from page 7 to 18. Please do not arbitrarily set other parameters unless you have understood the meaning ofeach parameter | |||
Setting | Default | Function | Explanation |
01P | 03 | Screen Backlight | 3 levels of the screen's brightness. |
02P | 01 | Distance Units | 0:KM; 1:MILE |
03P | 48 or 52 | Voltage | Motor Voltage. It should be set to the corresponding voltage value of the bicycle. Please do not change it to other voltage, it may cause damage to the motor. •For 48V bike, the value is 48; for 52V bike, please set the value to 52. |
04P | 010 | Auto Sleep Time | LCD display auto sleep time, no operation within the setting time, will auto sleep and quiet out the setting mode. The sleep time range is 1 to 60 minutes, 0 means no sleep. |
05P | 05 | Pedal Assist Level Setting | The available PAS level settings are: 0~3, 1~3, 0~5, 1~5. EBycco bikes all have 5 pedal assist levels that need to be set to 0-5; if you set it to 1-5, it turns off the PAS=0 function. Please don't change it to 0-3 or 1-3 at will or the speed display on the LCD will be messed up. |
06P | 26 or 28 or 29 |
Wheel Diameter | Please set the value of 06P according to the wheel diameter of the bike, any changes may cause inaccurate speed display. • 29: E8/E9 models are 29'' wheels, so the value needs to be set to 29; • 28: EB7Pro/E9Plus/G7/V7 are 26'' wheels, but due to thicker tires, the wheel diameter needs to be set to 28. • 26: EB10 |
07P | 001 | Speed Sensor Magnetic | Non-professionals do not change, change might cause speed error. |
08P | 100 or 62 | Speed Limited | •If you set "P08" to the maximum value, the speed is not limited: When "P02"=00, it means the unit of speed is "KM/H", and the maximum value of P08 can be set to 100; When "P02"=01, it means the unit of speed is "MPH", and the maximum value of P08 can be set to 62; •If you want to limit the maximum speed: When "P02"=00, the unit of speed is "KM/H", set "P02" to 32, then the fastest speed will not be more than 32KM/H; When "P02"=01, the speed unit is "MPH", set "P02" to 20, then the fastest speed will not exceed 20MPH; |
09P | 00 | Throttle Zero Start | 00: Throttle active when powers on. 01: Throttle only active after a few pedalling. |
10P | 02 | Drive Mode | 00: PAS active,Throttle inactive; 01: Throttle active,PAS inactive 02 10P Drive Mode 02: Both PAS and throttle active |
11P | 02 | PAS Sensitivity | Sensitivity of the PAS sensor. The higher the number set, the more crank revolutions are required to turn the motor on. Setting a lower number requires only a small number of crank turns to start the motor. |
12P | 03 | PAS Start Strength | Strength of PAS, strength goes up from 0 to 5 |
13P | 12 | PAS Sensor Magnetic | Non-professionals do not change |
14P | 28 | Controller Current Limit | Non-professionals do not change |
15P | 40.0 | Battery Undervoltage Value | The value can be ad justed based on the curent rated voltage |
16P | 00 | ODO Resetting | 00: non reset; 01: reset |
17P | 01 | Cruiser ModeON/OFF | 00: non enable; 01: enable |
18P | 01 | Walk Mode ON/oFF | 00: turn off walk boost function; 01:turn on walk boost function. |
19P | Psd-n | Password Setting | The power-on password is not activated by default but users can activate it from setting PSd-y. The factory default password is 1212. Users can set other four-digit password. Please keep the password in mind after changing it, otherwise you will not be able to use the display! |